Solid dielectric (EPDM molded rubber) vacuum load break switches (MVS) and vacuum fault interrupters (MVI), used alone or built into pad-mounted, vault and riser-pole multi-way switchgear.. Also sold as Thomas & Betts Elastimold MVS, ABB Elastimold MVI, Elastimold molded vacuum switch, Elastimold multi-way switchgear. New surplus, used, or failed. Send the nameplate, get a written offer.

Get an offer

What it is

Photograph the label on each MVS or MVI module showing the full catalog number. If the modules are inside a pad-mounted enclosure, photograph the enclosure nameplate and any control or relay too.

TypeSolid dielectric (EPDM molded rubber) vacuum load break switches (MVS) and vacuum fault interrupters (MVI), used alone or built into pad-mounted, vault and riser-pole multi-way switchgear.
ManufacturerElastimold, Thomas & Betts Elastimold MVS, ABB Elastimold MVI, Elastimold molded vacuum switch, Elastimold multi-way switchgear
On the nameplateMVS, MVI, RMVI, MVS1, MVS3, MVI1, MVI3
Voltage classes15 kV (15.5 to 17 kV max, 95 kV BIL), 27 kV (29 kV max, 125 kV BIL), 38 kV (150 kV BIL)
ContinuousMVS 600 A, MVI 630 A, 900 A eight-hour overload
MVI interrupting12.5 kA sym standard, 16, 20 or 25 kA on specific versions
MVS one-second rating12.5 kA sym
InsulationEPDM molded rubber, submersible, no oil or gas
Interfaces200 A bushing wells or 600 A bushings
Read the catalog number

How to read a Elastimold MVS and MVI molded vacuum switchgear catalog number.

The catalog number starts with an optional prefix (R riser pole, N network, W wind farm, none for subsurface), then MV, then S for switch or I for interrupter, then 1 or 3 for phases, then the fixed digits 21. Next comes the voltage class: 15, 27 or 38 (15A, 15B and 38B are higher-current interrupter versions). Then the end interface and main interface: 2 is a 200 A bushing well, 6 is a 600 A bushing. Letters after that are accessories, such as PS for a parking stand or MO120A for a 120 Vac motor operator.

MVI3212766PS
Three-phase molded vacuum interrupter, 27 kV, 600 A bushings both sides, parking stands
MVS1-21-15-22-PS
Single-phase molded vacuum switch, 15 kV, 200 A bushing wells both sides, parking stand
MVS3-21-38-66-PS
Three-phase molded vacuum switch, 38 kV, 600 A bushings both sides, parking stand
MVS3-21-15-22-PS
Three-phase molded vacuum switch, 15 kV, 200 A bushing wells, parking stand
RMVI3-21-27-6ABX
Riser-pole three-phase interrupter, 25 kV class, 600 A with air bushings

Not sure? Type it into the catalog lookup or text a photo of the label.

What drives the number
  • Three-phase modules (MVS3, MVI3) and 38 kV ratings bring more than single-phase 15 kV modules.
  • Motor operators and complete controls add value.
  • Higher-current interrupters (25 kA 38B, 20 kA 15A) are worth more than 12.5 kA standard units.
  • Torn or cracked rubber and damaged bushings reduce value.
  • We do not publish prices. Metal, demand, and condition move them. You get a written number for your unit.
From the yard

These are compact enough to fit in tight pad-mount, vault and riser-pole spaces, and a single-phase MVS weighs about 30 lbs. MVI interrupters carry an electronic control that needs no batteries or external power, with field-selectable fuse or relay curves. The modules are hotstick operated, and motor operators were offered as 120 Vac (MO120A) or 12 to 24 Vdc (MO12D) add-ons. Multi-way gear built from these modules carries its own catalog number for the assembled enclosure.

Photos we need

Three photos price most Elastimold MVS and MVI molded vacuum switchgear offers.

01

The nameplate

Straight on and readable. Voltage, ratings, model, and serial in frame.

02

Inside

Doors open: bus, devices, controls, and anything burned or missing.

03

The whole unit

A wide shot plus what is around it, so we can plan the pick.

The nameplate is usually on the inside of a door or on the dead-front barrier. Shoot it straight on with the voltage class, BIL, continuous and interrupting ratings, and the model or catalog number in frame. On SF6 gear, photograph the pressure gauge too.

How selling works
  1. 01
    Send the nameplate

    Photos or a list with counts. Text, email, or the form.

  2. 02
    We read it and reply

    During business hours, by whatever contact method you picked.

  3. 03
    You get a written offer

    Per unit or per lot. Freight is in the number.

  4. 04
    We pick up and pay

    Our truck and our rigging. Wire or ACH within 3 business days of a passed inspection.

Freight: Pad-mounted switchgear runs from roughly 2,000 to well over 6,000 pounds depending on ways and insulation. Most units lift from the base with a forklift or a truck-mounted crane and ride a flatbed. We plan the rigging. You tell us what is around the pad.