USA Transformers
Home/Circuit breakers/Eaton/Westinghouse DHP magnetic air breakers
Eaton · Medium voltage magnetic air circuit breakers

Sell your Westinghouse DHP magnetic air breakers.

5 to 15kV classes, 1200 and 2000A. Running spares, untested, or for parts. Send the nameplate, get a written offer; we rack out, rig, and haul.

Get an offer

What this family is

Drawout, electrically operated, in metal-clad switchgear. Older utility and industrial metal-clad switchgear. Westinghouse built them; Eaton owns the line now.

TypeMedium voltage magnetic air circuit breakers
Type designations50DHP, 75DHP, 150DHP, DHP
Voltage5 to 15kV classes
Amperage1200 and 2000A
Poles3
Where they come fromOlder utility and industrial metal-clad switchgear. Westinghouse built them; Eaton owns the line now.
Read the catalog number

Voltage class times ten, then DHP, then the MVA interrupting class.

50DHP250
5kV class, magnetic air, 250 MVA class
150DHP500
15kV class, magnetic air, 500 MVA class
What drives the number
  • Original DHP units sell as spares to sites still running DHP lineups.
  • Arc chutes, contacts, and the operating mechanism decide the number. A complete, clean breaker is worth far more than a parts unit.
  • We do not publish prices. Metal, demand, and condition move them. You get a written number for your units.
From the yard

Air magnetic breakers like DHP are heavy, and the arc chutes are fragile. Do not stack them or move them without the proper lift truck. A cracked arc chute turns a spare into a parts unit.

Photos we need

Three photos price a medium voltage breaker.

01

The nameplate

Type, kV, continuous amps, interrupting rating, and control voltage. Straight on and readable.

02

The front and mechanism

The breaker front, the operation counter, and the charging motor or handle.

03

In the lineup

The breaker in its cubicle or on the floor, plus the switchgear nameplate if the gear is coming out too.

How selling works
  1. 01
    Send the nameplates

    Type, kV, continuous amps, interrupting rating, control voltage. Plus a photo of the lineup if the gear is coming out.

  2. 02
    We read them and reply

    During business hours, by text, call, or email.

  3. 03
    You get a written offer

    Per breaker or for the lineup, with the removal plan included. Subject to inspection.

  4. 04
    We rack out, rig, and haul

    Our crew and equipment, after your people de-energize and lock out. Wire or ACH within 3 business days of a passed inspection.

FAQ

Selling Westinghouse DHP magnetic air breakers: what people ask.

Often, yes. Plants and utilities still running DHP switchgear need spares, and new ones are not made.

Selling Westinghouse DHP magnetic air breakers? Send the nameplate.