Sell your GE Magne-Blast air breakers.

4.16 to 13.8kV nominal, 1200 and 2000A. Running spares, untested, or for parts. Send the nameplate, get a written offer; we rack out, rig, and haul.

Get an offer

What this family is

Drawout, removable and interchangeable elements in GE metal-clad switchgear. GE metal-clad switchgear from the fifties through the eighties, still running at utilities and plants.

TypeMedium voltage magnetic air circuit breakers
Type designationsAM-4.16, AM-13.8, AM4.16, AM13.8
Voltage4.16 to 13.8kV nominal
Amperage1200 and 2000A
Poles3
Where they come fromGE metal-clad switchgear from the fifties through the eighties, still running at utilities and plants.
Read the catalog number

AM (air magnetic), then nominal kV, then MVA class, then a design suffix.

AM-4.16-250
4.16kV, 250 MVA class, air magnetic
AM-13.8-500-7H
13.8kV, 500 MVA class, design 7H
What drives the number
  • Spares for running lineups are the main market.
  • Complete units with intact arc chutes, contacts, and operating mechanism carry the most.
  • We do not publish prices. Metal, demand, and condition move them. You get a written number for your units.
From the yard

The letters and numbers after the MVA class, like -7H, identify the design version, and buyers match on it. That suffix is the first thing they ask for, so make sure it is readable in the nameplate photo.

Photos we need

Three photos price a medium voltage breaker.

01

The nameplate

Type, kV, continuous amps, interrupting rating, and control voltage. Straight on and readable.

02

The front and mechanism

The breaker front, the operation counter, and the charging motor or handle.

03

In the lineup

The breaker in its cubicle or on the floor, plus the switchgear nameplate if the gear is coming out too.

How selling works
  1. 01
    Send the nameplates

    Type, kV, continuous amps, interrupting rating, control voltage. Plus a photo of the lineup if the gear is coming out.

  2. 02
    We read them and reply

    During business hours, by text, call, or email.

  3. 03
    You get a written offer

    Per breaker or for the lineup, with the removal plan included. Subject to inspection.

  4. 04
    We rack out, rig, and haul

    Our crew and equipment, after your people de-energize and lock out. Wire or ACH within 3 business days of a passed inspection.

FAQ

Selling GE Magne-Blast air breakers: what people ask.

Yes. A lot of GE switchgear from that era is still energized, and the people running it need spares.

Selling GE Magne-Blast air breakers? Send the nameplate.