Eaton · Medium voltage vacuum circuit breakers

Sell your Eaton and Westinghouse VCP-W vacuum breakers.

5, 7.5, and 15kV classes, 1200, 2000, and 3000A. Running spares, untested, or for parts. Send the nameplate, get a written offer; we rack out, rig, and haul.

Get an offer

What this family is

Drawout, in metal-clad switchgear. Utility substations, plant 4160V and 13.8kV distribution, hospitals, and data centers. Westinghouse built the first ones; later units carry Cutler-Hammer and Eaton labels.

TypeMedium voltage vacuum circuit breakers
Type designations50VCP-W, 75VCP-W, 150VCP-W, VCP-W
Voltage5, 7.5, and 15kV classes
Amperage1200, 2000, and 3000A
Poles3
Where they come fromUtility substations, plant 4160V and 13.8kV distribution, hospitals, and data centers. Westinghouse built the first ones; later units carry Cutler-Hammer and Eaton labels.
Read the catalog number

Voltage class times ten, then VCP-W, then the MVA interrupting class.

50VCP-W250
5kV class, vacuum, 250 MVA class
150VCP-W500
15kV class, vacuum, 500 MVA class
What drives the number
  • Complete, tested breakers with the racking mechanism and secondary disconnects intact carry the most.
  • A matched set out of one lineup sells better together than one at a time.
  • Recent test sheets (insulation, contact resistance, timing) move the number up.
  • We do not publish prices. Metal, demand, and condition move them. You get a written number for your units.
From the yard

The control voltage on the nameplate, for example 125VDC close and trip, decides which switchgear a breaker can go into without rework. Buyers ask for it first, so get it in the nameplate photo.

Photos we need

Three photos price a medium voltage breaker.

01

The nameplate

Type, kV, continuous amps, interrupting rating, and control voltage. Straight on and readable.

02

The front and mechanism

The breaker front, the operation counter, and the charging motor or handle.

03

In the lineup

The breaker in its cubicle or on the floor, plus the switchgear nameplate if the gear is coming out too.

How selling works
  1. 01
    Send the nameplates

    Type, kV, continuous amps, interrupting rating, control voltage. Plus a photo of the lineup if the gear is coming out.

  2. 02
    We read them and reply

    During business hours, by text, call, or email.

  3. 03
    You get a written offer

    Per breaker or for the lineup, with the removal plan included. Subject to inspection.

  4. 04
    We rack out, rig, and haul

    Our crew and equipment, after your people de-energize and lock out. Wire or ACH within 3 business days of a passed inspection.

FAQ

Selling Eaton and Westinghouse VCP-W vacuum breakers: what people ask.

Yes, and we can rack them out and haul the lineup. Send the nameplates and a photo of the gear.

Selling Eaton and Westinghouse VCP-W vacuum breakers? Send the nameplate.