Sell your Square D KA, LA, MA, and Q2 frames breakers.
KA, KH, KC, KI, KAL, KHL, KCL, LA and more. 70 to 1000A, 240, 480, 600V. New in box, panel takeouts, used, and lots. Send the label, get a written offer.
Get an offerWhat this family is
I-Line plug-on and unit mount. Q2 is the older 240V Q-frame. Feeders in I-Line switchboards and panelboards, mains in older distribution equipment.
| Type | Legacy molded case feeder breakers |
|---|---|
| Catalog prefixes | KA, KH, KC, KI, KAL, KHL, KCL, LA, LH, LC, LI, LAL, LHL, LCL, LIL, LHP, MA, MH, Q2 |
| Voltage | 240, 480, 600V |
| Amperage | 70 to 1000A |
| Poles | 2, 3 |
| Where they come from | Feeders in I-Line switchboards and panelboards, mains in older distribution equipment. |
Series + poles + voltage digit + amps.
Interrupting class: A, then H, then C, same as the F-frame. I marks current limiting versions.
- Feeder sizes carry real value as tested used, especially 225 to 400A.
- Units still on their I-Line brackets, with jaws in good shape, sell as replacements for gear that is still running.
- We do not publish prices. Metal, demand, and condition move them. You get a written number for your units.
These frames often come out of switchboards still bolted to their I-Line hardware. Leave the hardware on. A breaker pried loose with a bar usually costs more in damage than the hour it saved.
27 Square D KA, LA, MA, and Q2 frames catalog numbers we see in the market.
Yours not on the list? We still buy it. This is a sample of what trades, not a limit.
- KA36110
- KA36125
- KA36150
- KA36175
- KA362001021
- KA36250
- KAL361251021
- KAL36250
- KC34110
- KC34150
- KC34225
- KCL34225
- KHL36000M8041
- LA36225
- LA36300
- LA36400
- LAL36400
- LAL36400MB
- LC36300
- LC36400
- LC36600
- LHL36350
- LHP36400MT
- LIL364008041
- Q232100
- Q232125
- Q232200
Three photos price most breaker lots.
The label
The catalog number, straight on and in focus. On a pile, line them up with labels facing the camera.
The business end
Line and load terminals, I-Line jaws or bolt-on tabs, and the trip unit or rating plug if it has one.
The lot
The whole shelf, bin, or pallet, with a rough count. New in box: the box labels.
Square D prints the catalog number on the face label. On PowerPact and Micrologic units, add a photo of the trip unit.
- 01Photograph the labels
One clear shot of each catalog number, or the whole shelf with labels facing the camera. A list with counts works for new in box.
- 02We read them and reply
During business hours, by text, call, or email, whichever you picked.
- 03You get a written offer
Per breaker or per lot. Subject to inspection on pickup.
- 04We pick up and pay
Our freight. Wire or ACH within 3 business days of a passed inspection.
Selling Square D KA, LA, MA, and Q2 frames: what people ask.
Often, yes. Old switchboards outlive their breakers, and the people running them need like-for-like replacements. Condition of the case and the jaws decides it.
Yes, and we can pull them. Tell us the switchboard is coming out and we price the breakers and the gear together.
Both. New in box, panel takeouts, tested used, untested used, and cosmetic damage all sell. Condition sets the number, not whether we buy.
We sort it from your photos into what resells as a unit and what goes by weight, then make one offer for the lot. Clear label photos are what make that fast.