USA Transformers
Home/Circuit breakers/Siemens/Siemens Sentron E-frame
Siemens · Molded case breakers

Sell your Siemens Sentron E-frame breakers.

ED2, ED4, ED6, HED4, HHED6, CED6, HHED, HED and more. 15 to 125A, 240V (ED2), 480V (ED4, HED4), 600V (ED6, HHED6, CED6). New in box, panel takeouts, used, and lots. Send the label, get a written offer.

Get an offer

What this family is

Panelboard and switchboard mounting or enclosures. Supplied with load-side lugs. Siemens panelboards and switchboards, enclosures, OEM equipment.

TypeMolded case breakers
Catalog prefixesED2, ED4, ED6, HED4, HHED6, CED6, HHED, HED, CED
Voltage240V (ED2), 480V (ED4, HED4), 600V (ED6, HHED6, CED6)
Amperage15 to 125A
Poles1, 2, 3
Where they come fromSiemens panelboards and switchboards, enclosures, OEM equipment.
Read the catalog number

Type (voltage class in the name) + poles + trip letter + amps.

ED63B100
ED6 (600V frame), 3-pole, B (standard thermal-magnetic), 100A
ED43B060
ED4 (480V frame), 3-pole, 60A
HHED63M125
HHED6, 3-pole, 125A, higher interrupting
CED63B030
CED6, 3-pole, 30A, current limiting class

Interrupting class: ED, then HED, then HHED, then CED.

What drives the number
  • HHED6 and CED6 carry more than ED6.
  • Panel takeouts in quantity are a common lot.
  • We do not publish prices. Metal, demand, and condition move them. You get a written number for your units.
From the yard

On a Siemens E-frame, the digit in the type is the voltage class, not the poles: ED6 is the 600V frame, and the poles come next. ED63B100 reads ED6, 3-pole, 100A. Misreading that digit is the most common mistake we see on Siemens lists.

Catalog numbers we buy

21 Siemens Sentron E-frame catalog numbers we see in the market.

Yours not on the list? We still buy it. This is a sample of what trades, not a limit.

  • CED63B015
  • CED63B030
  • CED63B060
  • ED42B040
  • ED43B020
  • ED43B100
  • ED43B125
  • ED63A125
  • ED63B070
  • ED63B090
  • ED63B100
  • ED63S125A
  • HED43B050
  • HED43B060
  • HED43B100
  • HHED63B020
  • HHED63B025
  • HHED63B030
  • HHED63B060
  • HHED63M100
  • HHED63M125
Photos we need

Three photos price most breaker lots.

01

The label

The catalog number, straight on and in focus. On a pile, line them up with labels facing the camera.

02

The business end

Line and load terminals, I-Line jaws or bolt-on tabs, and the trip unit or rating plug if it has one.

03

The lot

The whole shelf, bin, or pallet, with a rough count. New in box: the box labels.

The Sentron type (ED6, FXD6, JXD6) is printed on the face separately from the full catalog number. Get both in the photo.

How selling works
  1. 01
    Photograph the labels

    One clear shot of each catalog number, or the whole shelf with labels facing the camera. A list with counts works for new in box.

  2. 02
    We read them and reply

    During business hours, by text, call, or email, whichever you picked.

  3. 03
    You get a written offer

    Per breaker or per lot. Subject to inspection on pickup.

  4. 04
    We pick up and pay

    Our freight. Wire or ACH within 3 business days of a passed inspection.

FAQ

Selling Siemens Sentron E-frame: what people ask.

No. They share two letters and nothing else. Siemens puts a voltage digit right after ED (ED6); Eaton does not (ED3200).

Selling Siemens Sentron E-frame breakers? Send a photo of the label.