Sell your Siemens Sentron E-frame breakers.
ED2, ED4, ED6, HED4, HHED6, CED6, HHED, HED and more. 15 to 125A, 240V (ED2), 480V (ED4, HED4), 600V (ED6, HHED6, CED6). New in box, panel takeouts, used, and lots. Send the label, get a written offer.
Get an offerWhat this family is
Panelboard and switchboard mounting or enclosures. Supplied with load-side lugs. Siemens panelboards and switchboards, enclosures, OEM equipment.
| Type | Molded case breakers |
|---|---|
| Catalog prefixes | ED2, ED4, ED6, HED4, HHED6, CED6, HHED, HED, CED |
| Voltage | 240V (ED2), 480V (ED4, HED4), 600V (ED6, HHED6, CED6) |
| Amperage | 15 to 125A |
| Poles | 1, 2, 3 |
| Where they come from | Siemens panelboards and switchboards, enclosures, OEM equipment. |
Type (voltage class in the name) + poles + trip letter + amps.
Interrupting class: ED, then HED, then HHED, then CED.
- HHED6 and CED6 carry more than ED6.
- Panel takeouts in quantity are a common lot.
- We do not publish prices. Metal, demand, and condition move them. You get a written number for your units.
On a Siemens E-frame, the digit in the type is the voltage class, not the poles: ED6 is the 600V frame, and the poles come next. ED63B100 reads ED6, 3-pole, 100A. Misreading that digit is the most common mistake we see on Siemens lists.
21 Siemens Sentron E-frame catalog numbers we see in the market.
Yours not on the list? We still buy it. This is a sample of what trades, not a limit.
- CED63B015
- CED63B030
- CED63B060
- ED42B040
- ED43B020
- ED43B100
- ED43B125
- ED63A125
- ED63B070
- ED63B090
- ED63B100
- ED63S125A
- HED43B050
- HED43B060
- HED43B100
- HHED63B020
- HHED63B025
- HHED63B030
- HHED63B060
- HHED63M100
- HHED63M125
Three photos price most breaker lots.
The label
The catalog number, straight on and in focus. On a pile, line them up with labels facing the camera.
The business end
Line and load terminals, I-Line jaws or bolt-on tabs, and the trip unit or rating plug if it has one.
The lot
The whole shelf, bin, or pallet, with a rough count. New in box: the box labels.
The Sentron type (ED6, FXD6, JXD6) is printed on the face separately from the full catalog number. Get both in the photo.
- 01Photograph the labels
One clear shot of each catalog number, or the whole shelf with labels facing the camera. A list with counts works for new in box.
- 02We read them and reply
During business hours, by text, call, or email, whichever you picked.
- 03You get a written offer
Per breaker or per lot. Subject to inspection on pickup.
- 04We pick up and pay
Our freight. Wire or ACH within 3 business days of a passed inspection.
Selling Siemens Sentron E-frame: what people ask.
No. They share two letters and nothing else. Siemens puts a voltage digit right after ED (ED6); Eaton does not (ED3200).
Yes. Older gear in the Siemens family tree may carry those labels.
Both. New in box, panel takeouts, tested used, untested used, and cosmetic damage all sell. Condition sets the number, not whether we buy.
We sort it from your photos into what resells as a unit and what goes by weight, then make one offer for the lot. Clear label photos are what make that fast.