
Sell your Hammond Power Solutions cast resin transformer.
Medium voltage cast resin dry-type distribution transformer up to 35 kV class. Also sold as HPS cast resin, Hammond cast coil transformer. New surplus, used, or failed. Send the nameplate, get a written offer.
Get an offerWhat it is
Photograph the nameplate, each coil face, the HV and LV connections and any fan or temperature controller.
| Type | Medium voltage cast resin dry-type distribution transformer up to 35 kV class |
|---|---|
| Manufacturer | Hammond Power Solutions, HPS cast resin, Hammond cast coil transformer |
| kVA | 300 to 3000 kVA self-cooled; 4000 kVA fan-cooled |
| Primary | Up to 34.5 kV class, up to 150 kV BIL |
| Secondary | 208Y/120 to 600Y/347, or 2.4 to 5 kV |
| Rise | 80 C or 115 C standard |
| Insulation | 150 C or 180 C class systems |
| Enclosure | Type 1, 3R, 4/4X or 12 |
| Listing | UL 1562 up to 3 MVA; CSA C22.2 No. 47 |
- kVA and primary voltage set demand.
- Fan cooling and a working temperature controller add value.
- Resin cracks or tracking are a major deduction.
- Units with a matching enclosure in good shape are easier to place.
- We do not publish prices. Metal, demand, and condition move them. You get a written number for your unit.
Hammond casts these in mineral-filled epoxy with fiberglass reinforcement around copper or aluminum conductors. UL 1562 listing covers units up to 3 MVA, so larger units carry CSA or project-specific approval. Like any cast coil, a damaged coil cannot be repaired by re-dipping.
Three photos price most Hammond Power Solutions cast resin transformer offers.
The nameplate
Straight on and readable. Voltage, ratings, model, and serial in frame.
Inside
Doors open: bus, devices, controls, and anything burned or missing.
The whole unit
A wide shot plus what is around it, so we can plan the pick.
Nameplate is on the enclosure frame. Photograph it plus each cast coil face through the enclosure. These units are bought heavily on visuals, so more photos is genuinely more money.
- 01Send the nameplate
Photos or a list with counts. Text, email, or the form.
- 02We read it and reply
During business hours, by whatever contact method you picked.
- 03You get a written offer
Per unit or per lot. Freight is in the number.
- 04We pick up and pay
Our truck and our rigging. Wire or ACH within 3 business days of a passed inspection.
Freight: Comparable to MV dry-type but denser: a 1500 kVA pair can be 15,000 pounds of freight. Indoor removal from electrical rooms and penthouses is normal; send the route and we bring the plan.
Selling a Hammond Power Solutions cast resin transformer: what people ask.
Yes, with or without it. Send photos of both.
No oil is used in cast resin units. We still need the nameplate and site details.
Yes. Send the test report if you have one and we quote it as failed.
Both. New surplus, used, untested, and failed all sell. Condition sets the number, not whether we buy.
